    Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.
    Advertisement
    Scientific Reports volume 13, Article number: 1620 (2023) Cite this article
    1 Altmetric
    Metrics details
    Retrospective cohort study. To validate computed tomography (CT) radiodensity in Hounsfield units (HU) as a prognostic marker for pedicle screw loosening or cage subsidence in minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). The retrospective study involved 198 patients treated with MI-TLIF. Screw loosening (SL), cage subsidence (CS), and fusion status were assessed by plain radiographs. The risk factors of SL and CS were identified using logistic regression. A total of 258 levels and 930 screws were analyzed. During a 2-year follow-up, 16.2% and 24.7% of patients had CS and SL respectively. The cut-off value of L1 HU for predicting SL or CS was 117. The L1 HU < 117 and BMI ≥ 25 were two independent risk factors. The risk of SL or CS was 4.1 fold in patients L1 HU < 117 and 2.6 fold in patients with BMI ≥ 25. For patients concurrently having BMI ≥ 25 and pre-op L1 HU < 117, the risk was 4.3 fold. Fusion rate and clinical outcome were comparable in patients with SL or CS. L1 HU < 117 and BMI > 25 were two independent risk factors that can be screened preoperatively for preventing SL or CS and lead to better management of patients undergoing MI-TLIF.
    Lumbar degenerative disease is prevailing worldwide causing refractory low back pain and neurological symptoms and may require surgery for management1. Transforaminal Lumbar Interbody Fusion (TLIF) is the preferred treatment choice for degenerative lumbar disease globally2, which was proposed in 1998 by Harms et al.3. TLIF is an effective method for the management of a variety of degenerative lumbar diseases. A recent study revealed good functional outcomes and fusion rates in patients who underwent TLIF4. Minimally invasive-TLIF (MI-TLIF), prevents peri-operative complications such as soft tissue or muscle injury and is associated with low estimated blood loss (EBL), fewer recovery days, and allowing early ambulation to preserve patients’ muscle power5.
    Cage subsidence and screw loosening are two common complications associated with TLIF with an incidence rate of 15–34%6,7,8 and 7–25%9,10 respectively. These complications may cause non-union and are associated with the clinical outcomes of back pain, leg pain, or diminished physical function11. Osteoporosis decreases bone strength (including bone quality and density), by altering the microarchitecture of the bone. Consequently, low bone mass may increase the complications associated with spine surgery12. Recent research has revealed that osteoporosis promotes complications including cage subsidence and screw loosening7,13,14, which significantly increases overall complications rates after TLIF15. Therefore, identifying patients with osteoporosis before surgery and managing it may largely reduce the incidence of surgical complications.
    Dual-energy X-ray absorptiometry (DXA) is the standard tool for evaluating bone mineral density (BMD)16. However, DXA associated with cortical margins of vertebrae, spinal degeneration such as osteophytes, vascular calcifications, scoliosis and post-spine surgery may be misinterpreted as increased BMD17. DXA is expensive and carries a risk of higher radiation exposure18. Alternatively, studies suggest using vertebral Hounsfield Units (HU), a quantitative scale for describing radiodensity from existing CT scans to evaluate BMD without additional cost, time, or radiation exposure. HU is a proven marker for osteoporosis19,20,21. The HU reading at the L1 level is being routinely used to study patients’ BMD of the lumbar spine19,22. The purpose of this investigation was to determine whether preoperatively obtained HU at L1 level is a prognostic marker for predicting cage subsidence or screw loosening in MI-TLIF and other associated risk factors.
    The study is based on the retrospective data collected at a single institute from October 2016 to February 2020. Institutional ethical approval was obtained before the start of this study by the Human Research Ethics Committee at Taipei Veterans General Hospital (IRB No. 2022-01-018AC). All methods were performed in accordance with the relevant guidelines and regulations, and all participants provided written, informed consent to participation.
    The inclusion criteria were as follows: (1) Adult patients (2) Underwent MI-TLIF at 1- or 2- levels. (3) Followed up for more than 2 years after surgery. (4) Underwent lumbar-CT scan within 6 months before surgery. The exclusion criteria were: (1) Spinal infection, trauma, or tumor (2) Prior spine surgery (3) Patients lost to follow-up. The patients were followed up on the 1st, 3rd, 6th, 12th, and 24th months following surgery. The patients were screened using the visual analog scale score, Oswestry disability index scores, and radiographs were obtained at each follow-up visit.
    All surgeries were performed by a single senior surgeon. The patient was placed in the prone position for fluoroscopy in the anteroposterior (AP) and lateral views to locate the affected level. The surgical procedure for MI-TLIF included skin incision 2–3 cm laterally from the midline with bilateral decompression and percutaneous pedicle screw insertion. We chose the same side showing sciatica symptoms to perform facetectomy. The decompression, disc preparation, and TLIF procedures were performed under a micro-endoscopic retractor-assisted microscopic visualization. A morselized autologous bone graft accompanied with a 1-ml demineralized bone matrix (OsteoSelect® DBM Putty, Bacterin International, Inc., Belgrade, MT, USA) was used for fusion in all patients. We did not use any bone substitutes to increase the bulk of the bone grafts. We used a banana-shaped polyetheretherketone (PEEK) cage (Rainboo® lumbar cage, A-SPINE, United Orthopedic Corporation, Taiwan) in all MI-TLIF surgeries. There was no drainage tube insertion after the operation. Post-operative spinal bracing was prescribed to all patients for 3–6 months7.
    All data were collected through the electronic medical record and picture archiving communication system. Patient demographics and preoperative details such as age, sex, body mass index (BMI), comorbidities, surgical time, EBL, surgical level, and hospital stay were recorded. Overweight was defined as BMI ˃ 25, as per the international classification system of the World Health Organization.
    A single brand of CT scanner (iCT256; Philips Brilliance) was used for all participants. CT parameters included a slice thickness of 3 mm and a tube voltage of 120 kVp. Regions of interest (ROI) were selected on the axial images of lumbar non-contrast CT at three separate locations: immediately inferior to the superior end plate, in the middle of the vertebral body, and superior to the inferior end plate (Fig. 1). For each measurement, the largest possible elliptical ROI was drawn in the vertebral body, excluding the cortical margins, lateral walls, endplates, or obvious osteophytes to prevent volume averaging. The HU values from the three axial slices were averaged to give a mean HU value for each lumbar vertebral body19.
    Computed tomography images illustrating the measurement of the HU value in a series of axial views of L1 vertebrae. Regions of interest were measured on the axial images at three separate locations. Slice (A) was taken just inferior to the superior end plate, slice (B) was chosen at the middle of the body, and slice (C) was taken just superior to the inferior end plate. Averaged HU values of the three axial slices were cut-off HU values for L1 vertebrae. HU hounsfield units.
    Radiographic parameters were obtained by standing anterior–posterior lateral plain radiographs. Index-level segmental lordosis was defined as the angle formed between the intersection of lines parallel to the superior endplate of the cephalic surgical vertebra and the inferior end plate of the caudal surgical vertebra on the lateral radiographs. Cage position was evaluated using a central point ratio (CPR), which is the ratio of the distance between the cage midpoint to the posterior edge of the superior endplate of the inferior vertebra (a) divided by the length of the superior endplate of the inferior vertebra (b) given by: (a/b × 100%)7. A CPR > 0.5 indicated a more anteriorly displaced cage. Two lines parallel to the inferior endplate of the superior vertebra and the superior end plate of the inferior vertebra of a disc space formed an intersection. The angle was defined as disc angle23. Disc height was measured as the average of the anterior and posterior edges of the disc space24 (Fig. 2). A ≥ 2 mm migration of the cage into the adjacent vertebral body was defined as cage subsidence. The migration along the superior and/or inferior end plates were labeled as settling of the implant6 (Fig. 3). Screw loosening was defined as the presence of at least 1 mm thick radiolucent zone around any pedicle screws25 (Fig. 4). The criteria for a solid fusion were defined as bone bridges with at least half of the fusion area with a minimum density as originally achieved at surgery, is considered to be mechanically solid fusion according to BSF (Brantigan, Steffee, Fraser) Criteria26.
    (1) The central point ratio (CPR) is the ratio of the distance between the midpoint of the cage and the posterior edge of the endplate (a); divided by the length of the superior endplate of the inferior vertebra (b). CPR = a/b × 100%. (2) Segmental lordosis angle (c) was measured at two lines parallel to the superior endplate of the cephalic surgical vertebra and the inferior end plate of the caudal surgical vertebra of the index level. (3) Disc height. Two vertical lines (e) and (f) are set at the anterior and posterior edge of the disc space, and the average of e and f was defined as the disc height. (4) Disc angle. Two lines parallel to the inferior endplate of the superior vertebra, intersect with the superior end plate of the inferior vertebra of disc space to form an angle. The angle (d) was defined as the disc angle.
    Cage subsidence was defined as a cage migrating more than 2 mm into the superior or inferior endplate of adjacent vertebrae.
    Screw loosening was defined as the presence of at least 1 mm thick radiolucent zone around any pedicle screw (Halo sign). Bilateral halo sign is evident on L3 level.
    Statistical analyses were performed using IBM SPSS Statistics, Version 25.0 (IBM Corp., Armonk, NY, USA). Chi-square and Fisher exact tests were used to compare the categorical data of the two groups. Independent t test was used to compare continuous data. To identify the risk factors for cage subsidence or screw loosening, a univariate logistic regression (LR) analysis was performed. Variables with P ≤ 0.1 in univariate analyses were entered into a logistic regression model. The results were presented as odds ratios (OR), with 95% confidence intervals (CI). The receiver operating characteristics curve (ROC) was used to evaluate the value of HU for predicting cage subsidence and screw loosening; the area under the curve (AUC) was calculated. The two-tailed significance level was set at P < 0.05.
    Our study included 198 patients with 258 levels and 930 screws. The mean follow-up period for these patients was 25.3 months. Among 198 patients, 131 were female (66.2%) and 67 were male (33.8%). The mean age of patients was 66.9 years. Most patients underwent single-level surgery (61.6%), with the most affected level being L4-L5 (44.4%) (Table 1).
    During the 2-year follow-up, 32 patients had cage subsidence (16.2%), 49 patients had screw loosening (24.7%), and none of the patients encountered breaking of screws. Out of 258 cages, 34 occurrences of cage subsidence were noted, and the incidence rate of cage subsidence by the number of cages was 13.2%. Out of 930 screws that were analyzed, 100 screw loosening occurrences were noted, and the incidence rate of screw loosening by the number of screws was 10.8%.
    We classified patients into two groups: patients who encountered cage subsidence or screw loosening were classified into the “CS/SL” group. Patients who did not encounter cage subsidence and screw loosening were classified into the “Non-CS/SL” group.
    There were 70 patients (35.3%) in the CS/SL group.
    The preoperative L1 HU was significantly lower in the CS/SL group than in the Non-CS/SL group (108.3 ± 45.3 vs. 139.8 ± 51.7, P < 0.001). There were no significant differences in age, sex, diabetes, hypertension, and smoking habits between the two groups (Table 2).
    There were more overweight patients (72.9%, P = 0.009) in the CS/SL group. Cage position, disc angle, disc height and index level segmental lordosis were not significantly different between the two groups at the preoperative and postoperative stages. The cut-off value for the mean HU used to predict cage subsidence or screw loosening was 117 (sensitivity: 67.1%, specificity: 66.4%). The AUC was 0.686 (95% CI 0.608–0.765, P < 0.001).
    The result of multivariate LR analysis showed that the variables ‘overweight’ and ‘L1 HU < 117’ were significant risk factors associated with cage subsidence or screw loosening. The risk of cage subsidence or screw loosening increased 2.596-fold (95% CI 1.328–5.075, P = 0.005) in overweight patients (BMI ≥ 25) and 4.100-fold in patients with lower preoperative ‘L1 HU < 117’ (95% CI 2.173–7.737, P < 0.001). Furthermore, for the patient with concurrent BMI ≥ 25 and L1 HU < 117, the OR was 4.291 with 95% CI 2.210–8.329, P < 0.001, and power = 0.991 (Table 3).
    Analyses of the clinical outcomes revealed that both groups had comparable pain-scale results and functional presentation preoperatively. The Non-CS/SL-group patients had lower pain-scale results and better functional outcomes. The overall fusion rate was 82%, and a lower fusion rate was noted in CS/SC group (75.7% vs. 84.4%); however, there was no significant difference between the groups (P = 0.135). Ten patients (5.1%) underwent revision surgery due to nonunion and symptomatic screw loosening, (four patients in Non-CS/SC group [3.1%]; six patients in CS/SC group [4.4%]. There was no significant difference between the groups (P = 0.171) (Table 4).
    TLIF involving pedicle screw fixation and interbody cage placement, is a common approach for spine fusion, in the majority of cases worldwide. Cage subsidence and screw loosening are the common mechanical complications of TLIF. There are various risk factors for the occurrence of these complications; however, low BMD is the most common risk factor7,13,14. Our investigation confirmed that HU at the first lumbar level can be used to determine BMD and to predict the occurrence of mechanical complications associated with MI-TLIF. Being overweight is also a significant risk factor for cage subsidence or screw loosening following MI-TLIF.
    A survey among spine surgeons showed that only 44% of them routinely opted for DXA examinations prior to instrumented fusion27. Degenerative changes in the lumbar spine can have a confounding effect by increasing the DXA scores of lumbar BMD, leading to false-negative results28. Alternatively, the lumbar CT is one of the routine examinations that is performed preoperatively. Spine surgeons may utilize the preoperative HU scores of the lumbar CT scan instead of DXA, to evaluate whether patients are vulnerable to screw loosening or cage subsidence following MI-TLIF.
    The cage subsidence rate (16.2%) in our study was lower than that in other studies. Lin et al.29 showed that the cage subsidence rate was 36% after 12 months of radiograph follow-up. Yao et al.7 demonstrated that the cage subsidence rate was 34.1% in patients who underwent MI-TLIF surgery after 12 months of follow-up.
    Studies attribute the low density of the cancellous bone to its weakened ability to resist the compression, leading to cage subsidence. Meanwhile, CT-based HU values have shown a strong correlation with BMD, as the ability of bone to withstand compression. Jie et al.30 reported that the mean global lumbar HU values of patients with cage subsidence were significantly low vs. controls (112.4 vs. 140.2); HU of the surgical levels in patients with cage subsidence was also significantly low vs. controls (113.4 vs. 127.9). Their cut-off values were 132 for global and 122 for the surgical region.
    Barbosa et al.31 established the cut-off HU value of 135 at the L1 level to predict potential cage subsidence. They showed HU < 135 was an independent risk factor in cage subsidence with OR = 6 (95% CI 1.95–34) according to the multivariate analysis.
    Until recently, the correlation between BMI and cage subsidence was inconclusive. Most studies predicted that higher BMI may contribute to a higher risk of cage subsidence. Behrbalk et al.32 reported that patients who had subsidence after lumbar interbody fusion had significantly higher BMI vs. controls (29.2 vs. 22.1). In addition, Yao et al.7 reported significantly higher BMI in the cage subsidence group after TLIF vs. controls (27.5 vs. 25.9). Similarly, our study demonstrated that overweight patients had a 2.596-fold higher risk of cage subsidence or screw loosening after MI-TLIF.
    Previous studies have revealed that the position of the cage and the affected levels were risk factors for cage subsidence7. However, in our case, neither cage position nor the levels of fusion were statistically significant to be the risk factors. The contrast may be attributed to the fact that our surgeons can usually place the cage in similar positions; hence, the position of the two groups was not significantly different. There were other factors that had a much stronger impact than these two factors in cage subsidence.
    The screw loosening rate in our study (24.7%) was comparable to that of other studies. For example, Ohtori et al.9 and Kim et al.6 demonstrated that the screw loosening rate was 7–25% after 12 months of follow-up for short levels of fixation; Tokuhashi et al.33 reported the screw loosening rate was 26.8% after 12 months follow-up in patients who underwent 1–4 levels of fixation.
    Recent research has revealed that lower BMD has a detrimental effect on screw loosening. Poppenborg et al.13 reported that Osteoporosis, which is characterized by low BMD, was strongly associated with loosening. Bredow et al.34 reported screw loosening in 45 of 365 patients screened. The study revealed that the screw loosening group had a significantly lower CT-based HU vs. controls (116.3 vs. 132.7) and proposed the cut-off value of 120 HU for global HU. Schwaiger et al.35 performed a retrospective review of 38 patients who underwent CT imaging and found osteoporosis to be a significant risk factor for screw loosening in spine instrumentation. They used 117.9 HU as their cut-off which was obtained from the mean HU of L1, L2, and L3 levels, to identify patients with the risk of screw loosening. In a study involving 253 patients, Zou et al.28 reported a lower preoperative HU in patients with screw loosening vs. controls (106.8 vs. 129.8). The cut-off value, for identifying high-risk patients in this study was 110 HU, which was obtained from mean HU of L1 to L4 levels.
    Risk factors of screw loosening have also been studied. Wu et al.36 reported that patients with diabetes mellitus had a significantly higher rate of screw loosening compared to controls (36.0% vs. 15.8%; p = 0.024). In addition, well-controlled serum glucose (HbA1c ≤ 8.0%) was shown to significantly reduce the chance of screw loosening (28.6% vs. 71.4%; p = 0.021). Yasushi et al.37 showed that high BMI was a risk factor for screw loosening after lumbosacral fixation. Studies showed that obesity may increase the mechanical stress of the posterior instrument due to the change in body shape, which could increase the screw loosening rate. These findings corresponded to our investigation.
    Our study is the first to investigate risk factors of cage subsidence and screw loosening simultaneously and propose the HU cut-off to predict these complications after MI-TLIF. Low preoperative L1 HU and being overweight are indeed significant risk factors for cage subsidence and screw loosening following MI-TLIF. Our findings are novel and could promote better surgical planning. Consequently, for patients whose preoperative L1 HU < 117, pedicle screw fixation with bone cement augmentation38 and administration of teriparatide9 can be considered to prevent screw loosening. Controlling BMI by losing weight before lumbar fusion surgery also can prevent the occurrence of both cage subsidence, and screw loosening. Furthermore, endplate sclerosis at surgical levels may prevent the discovery of cage subsidence following lumbar fusion surgery39.
    Our study has a few limitations. Firstly, we did not investigate the relationship between cage subsidence and endplate injury during surgery. Destruction of the endplate is a potential factor for cage subsidence. However, all patients were all operated on by a single surgeon, with a consistent surgical technique. We did not measure index level HU, which can be another limitation. Different scanning protocols may affect the results of HU, and we applied only one type of CT scanner in the study. Asynchronous phantom-calibrated CT may be a solution to improve accuracy and precision of measuring the BMD40. Nico Sollmann et al.41. proposed a study that HU measurments using asynchronous phantom-calibrated can have better correlation to results from QCT. However, multiple conversion formula were proposed based on different type of CT scan and parameters, we still cannot to choose a single formula to calibrate HU generally, which is a focus for future efforts.
    In conclusion, pre-operative L1 CT HU is a good predictor of cage subsidence or screw loosening in MI-TLIF. Patients with both a pre-op L1 HU < 117 and a BMI > 25 may be 4.29 times more likely to experience cage subsidence or screw loosening. Therefore, L1 HU < 117 and BMI > 25 were two independent risk factors that can be screened preoperatively for preventing SL or CS and lead to better management of patients undergoing MI-TLIF.
    The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.
    Ravindra, V. M. et al. Degenerative lumbar spine disease: Estimating global incidence and worldwide volume. Glob. Spine J. 8, 784–794 (2018).
    Article  Google Scholar 
    McAfee, P. C. et al. The indications for interbody fusion cages in the treatment of spondylolisthesis: Analysis of 120 cases. Spine 30, S60–S65 (2005).
    Article  Google Scholar 
    Harms, J. G. & Jeszenszky, D. Die posteriore, lumbale, interkorporelle fusion in unilateraler transforaminaler Technik. Oper. Orthop. Traumatol. 10, 90–102 (1998).
    Article  CAS  Google Scholar 
    Hackenberg, L. et al. Transforaminal lumbar interbody fusion: A safe technique with satisfactory three to five year results. Eur. Spine J. 14, 551–558 (2005).
    Article  Google Scholar 
    Karikari, I. O. & Isaacs, R. E. Minimally invasive transforaminal lumbar interbody fusion: A review of techniques and outcomes. Spine 35, S294–S301 (2010).
    Article  Google Scholar 
    Kim, M.-C., Chung, H.-T., Cho, J.-L., Kim, D.-J. & Chung, N.-S. Subsidence of polyetheretherketone cage after minimally invasive transforaminal lumbar interbody fusion. Clin. Spine Surg. 26, 87–92 (2013).
    Google Scholar 
    Yao, Y.-C. et al. Risk factors of cage subsidence in patients received minimally invasive transforaminal lumbar interbody fusion. Spine 45, E1279–E1285 (2020).
    Article  Google Scholar 
    Marchi, L. et al. Radiographic and clinical evaluation of cage subsidence after stand-alone lateral interbody fusion. J. Neurosurg. Spine 19, 110–118 (2013).
    Article  Google Scholar 
    Ohtori, S. et al. Compariso of teriparatide and bisphosphonate treatment to reduce pedicle screw loosening after lumbar spinal fusion surgery in postmenopausal women with osteoporosis from a bone quality perspective. Spine 38, E487–E492 (2013).
    Article  Google Scholar 
    Kim, J. W., Park, S. W., Kim, Y. B. & Ko, M. J. The effect of postoperative use of teriparatide reducing screw loosening in osteoporotic patients. J. Korean Neurosurg.Soc. 61, 494 (2018).
    Article  CAS  Google Scholar 
    Hägg, O., Fritzell, P. & Nordwall, A. The clinical importance of changes in outcome scores after treatment for chronic low back pain. Eur. Spine J. 12, 12–20 (2003).
    Article  Google Scholar 
    Bjerke, B. T. et al. Incidence of osteoporosis-related complications following posterior lumbar fusion. Glob. Spine J. 8, 563–569 (2018).
    Article  Google Scholar 
    Poppenborg, P. et al. Complications in TLIF spondylodesis–do they influence the outcome for patients? A prospective two-center study. Eur. Spine J. 30, 1320–1328 (2021).
    Article  Google Scholar 
    Fritzell, P., Hägg, O. & Nordwall, A. Complications in lumbar fusion surgery for chronic low back pain: Comparison of three surgical techniques used in a prospective randomized study. A report from the Swedish Lumbar Spine Study Group. Eur. Spine J. 12, 178–189 (2003).
    Article  Google Scholar 
    Formby, P. M., Kang, D. G., Helgeson, M. D. & Wagner, S. C. Clinical and radiographic outcomes of transforaminal lumbar interbody fusion in patients with osteoporosis. Glob. Spine J. 6, 660–664 (2016).
    Article  Google Scholar 
    Organization, W. H. Prevention and management of osteoporosis. World Health Organ. Tech. Rep. Ser. 921, 1–164 (2003).
    Google Scholar 
    Rand, T. et al. Impact of spinal degenerative changes on the evaluation of bone mineral density with dual energy X-ray absorptiometry (DXA). Calcif. Tissue Int. 60, 430–433 (1997).
    Article  CAS  Google Scholar 
    Hemmingsson, E., Uddén, J. & Neovius, M. No apparent progress in bioelectrical impedance accuracy: Validation against metabolic risk and DXA. Obesity 17, 183–187 (2009).
    Article  Google Scholar 
    Schreiber, J. J., Anderson, P. A., Rosas, H. G., Buchholz, A. L. & Au, A. G. Hounsfield units for assessing bone mineral density and strength: A tool for osteoporosis management. JBJS 93, 1057–1063 (2011).
    Article  Google Scholar 
    Lee, S., Chung, C. K., Oh, S. H. & Park, S. B. Correlation between bone mineral density measured by dual-energy X-ray absorptiometry and Hounsfield units measured by diagnostic CT in lumbar spine. J. Korean Neurosurg. Soc. 54, 384 (2013).
    Article  Google Scholar 
    Hendrickson, N. R., Pickhardt, P. J., Del Rio, A. M., Rosas, H. G. & Anderson, P. A. Bone mineral density T-scores derived from CT attenuation numbers (Hounsfield units): Clinical utility and correlation with dual-energy X-ray absorptiometry. Iowa Orthop. J. 38, 25 (2018).
    Google Scholar 
    Chia, K. K., Haron, J. & Malek, N. F. S. N. Accuracy of computed tomography attenuation value of lumbar vertebra to assess bone mineral density. Malays. J. Med. Sci. 28, 41 (2021).
    Google Scholar 
    Damasceno, L. H. F., Catarin, S. R. G., Campos, A. D. & Defino, H. L. A. Lumbar lordosis: A study of angle values and of vertebral bodies and intervertebral discs role. Acta Ortop. Bras. 14, 193–198 (2006).
    Article  Google Scholar 
    Cheung, K. M., Zhang, Y., Lu, D., Luk, K. D. & Leong, J. C. Reduction of disc space distraction after anterior lumbar interbody fusion with autologous iliac crest graft. Spine 28, 1385–1389 (2003).
    Article  Google Scholar 
    Galbusera, F. et al. Pedicle screw loosening: A clinically relevant complication?. Eur. Spine J. 24, 1005–1016 (2015).
    Article  Google Scholar 
    Brantigan, J. W. & Steffee, A. D. Lumbar Fusion and Stabilization 379–395 (Springer, 1993).
    Book  Google Scholar 
    Dipaola, C. P. et al. Survey of spine surgeons on attitudes regarding osteoporosis and osteomalacia screening and treatment for fractures, fusion surgery, and pseudoarthrosis. Spine J. 9, 537–544 (2009).
    Article  Google Scholar 
    Zou, D., Li, W., Deng, C., Du, G. & Xu, N. The use of CT Hounsfield unit values to identify the undiagnosed spinal osteoporosis in patients with lumbar degenerative diseases. Eur. Spine J. 28, 1758–1766 (2019).
    Article  Google Scholar 
    Lin, G.-X. et al. Clinical and radiologic outcomes of direct versus indirect decompression with lumbar interbody fusion: A matched-pair comparison analysis. World Neurosurg. 119, e898–e909 (2018).
    Article  Google Scholar 
    Mi, J. et al. Vertebral body Hounsfield units are associated with cage subsidence after transforaminal lumbar interbody fusion with unilateral pedicle screw fixation. Clin. Spine Surg. 30, E1130–E1136 (2017).
    Article  Google Scholar 
    Amorim-Barbosa, T. et al. Risk factors for cage subsidence and clinical outcomes after transforaminal and posterior lumbar interbody fusion. Eur. J. Orthop. Surg. Traumatol. 32, 1–9 (2021).
    Article  Google Scholar 
    Behrbalk, E. et al. Fusion and subsidence rate of stand alone anterior lumbar interbody fusion using PEEK cage with recombinant human bone morphogenetic protein-2. Eur. Spine J. 22, 2869–2875. https://doi.org/10.1007/s00586-013-2948-5 (2013).
    Article  Google Scholar 
    Tokuhashi, Y., Matsuzaki, H., Oda, H. & Uei, H. Clinical course and significance of the clear zone around the pedicle screws in the lumbar degenerative disease. Spine 33, 903–908 (2008).
    Article  Google Scholar 
    Bredow, J. et al. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery. Arch. Orthop. Trauma Surg. 136, 1063–1067 (2016).
    Article  Google Scholar 
    Schwaiger, B. et al. Bone mineral density values derived from routine lumbar spine multidetector row CT predict osteoporotic vertebral fractures and screw loosening. Am. J. Neuroradiol. 35, 1628–1633 (2014).
    Article  CAS  Google Scholar 
    Wu, J.-C. et al. Pedicle screw loosening in dynamic stabilization: Incidence, risk, and outcome in 126 patients. Neurosurg. Focus 31, E9 (2011).
    Article  Google Scholar 
    Camp, J., Caudle, R., Ashmun, R. D. & Roach, J. Immediate complications of Cotrel-Dubousset instrumentation to the sacro-pelvis. A clinical and biomechanical study. Spine 15, 932–941 (1990).
    Article  CAS  Google Scholar 
    Chang, M.-C., Liu, C.-L. & Chen, T.-H. Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: A novel technique. Spine 33, E317–E324 (2008).
    Article  Google Scholar 
    Liu, J. et al. Modic changes (MCs) associated with endplate sclerosis can prevent cage subsidence in oblique lumbar interbody fusion (OLIF) stand-alone. World Neurosurg. 138, e160–e168 (2020).
    Article  ADS  Google Scholar 
    Kaesmacher, J., Liebl, H., Baum, T. & Kirschke, J. S. Bone mineral density estimations from routine multidetector computed tomography: A comparative study of contrast and calibration effects. J. Comput. Assist. Tomogr. 41, 217 (2017).
    Article  Google Scholar 
    Sollmann, N. et al. Automated opportunistic osteoporosis screening in routine computed tomography of the spine–comparison with dedicated quantitative CT. J. Bone Miner. Res. https://doi.org/10.1002/jbmr.4575 (2022).
    Article  Google Scholar 
    Download references
    Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan
    Yu-Cheng Yao, Hsi-Hsien Lin, Shih-Tien Wang, Ming-Chau Chang, Chien-Lin Liu & Po-Hsin Chou
    School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
    Yu-Cheng Yao, Hsien Chao, Kun-Yu Kao, Hsi-Hsien Lin, Shih-Tien Wang, Ming-Chau Chang, Chien-Lin Liu & Po-Hsin Chou
    Department of Medical Education, Chang Gung Memorial Hospital, Taoyuan, Taiwan
    Hsien Chao
    Department of Medical Education, Chi Mei Hospital, Tainan, Taiwan
    Kun-Yu Kao
    Kinmen Hospital, Ministry of Health and Welfare, Kinmen, Taiwan
    Shih-Tien Wang
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    You can also search for this author in PubMed Google Scholar
    Y.-C.Y. and P.-H.C. wrote the programs, designed the analysis. Y.-C.Y., H.C., K.-Y.K. and P.-H.C. analyzed the data, and wrote the paper. H.-H.L., S.-T.W., M.-C.C. and C.-L.L. supervised the conception and edited the manuscript. All authors discussed and commented on the manuscript.
    Correspondence to Po-Hsin Chou.
    The authors declare no competing interests.
    Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
    Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
    Reprints and Permissions
    Yao, YC., Chao, H., Kao, KY. et al. CT Hounsfield unit is a reliable parameter for screws loosening or cages subsidence in minimally invasive transforaminal lumbar interbody fusion. Sci Rep 13, 1620 (2023). https://doi.org/10.1038/s41598-023-28555-7
    Download citation
    Received: 26 July 2022
    Accepted: 20 January 2023
    Published: 28 January 2023
    DOI: https://doi.org/10.1038/s41598-023-28555-7
    Anyone you share the following link with will be able to read this content:
    Sorry, a shareable link is not currently available for this article.

    Provided by the Springer Nature SharedIt content-sharing initiative
    By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.
    Advertisement
    Scientific Reports (Sci Rep) ISSN 2045-2322 (online)
    © 2023 Springer Nature Limited
    Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

    source

    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Previous ArticleUpdate on US Food and Drug Administration Emergency Use … – AstraZeneca US
    Next Article UAE minister announces formation of new education councils – wknd.
    The Updates World

    Related Posts

    Education

    ESFA Update further education: 22 March 2023 – GOV.UK

    Education

    Meet this film star who scores full marks – The Indian Express

    Education

    BBC Radio 5 Live podcast investigates children missing from the … – BBC

    Add A Comment

    Leave A Reply Cancel Reply

    Subscribe to Updates

    Get the latest creative news from FooBar about art, design and business.

    RECENT POSTS

    ESFA Update further education: 22 March 2023 – GOV.UK

    March 25, 2023

    Meet this film star who scores full marks – The Indian Express

    March 25, 2023

    BBC Radio 5 Live podcast investigates children missing from the … – BBC

    March 25, 2023

    Ways to Give – UNICEF USA

    March 25, 2023
    ARCHIVES
    • March 2023 (1409)
    • February 2023 (1538)
    • January 2023 (1780)
    • December 2022 (1667)
    • November 2022 (1456)
    • October 2022 (1537)
    • September 2022 (880)
    • August 2022 (5)
    • July 2022 (19)
    • June 2022 (9)
    • Contact Us
    • Terms And Conditions
    • Privacy Policy
    • About Us
    • Sitemap
    • Disclaimer
    • DMCA
    Copyright © 2023 The Updates World.

    Type above and press Enter to search. Press Esc to cancel.